Daktronics Venus DataStreamer Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Daktronics Venus DataStreamer. Daktronics Venus DataStreamer User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 81
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
201 Daktronics Dr. PO Box 5128 Brookings SD 57006
Tel 866-343-3122 Fax 605-697-4700
www.daktronics.com
Venus
®
DataStreamer
®
Operation Manual
ED-13649 Rev 1022 July 2011
Przeglądanie stron 0
1 2 3 4 5 6 ... 80 81

Podsumowanie treści

Strona 1 - DataStreamer

201 Daktronics Dr. PO Box 5128 Brookings SD 57006 Tel 866-343-3122 Fax 605-697-4700 www.daktronics.com Venus® DataStreamer® Operation Manual

Strona 2 - DAKTRONICS, INC

4 Introduction About: Provides information about the software. Preview Current Frame/ Play Message Preview/ Stop Message Preview/ Pause Message Pre

Strona 3 - Table of Contents

Introduction 5 Weather: Insert new weather data into a message. The weather driver will collect data from external data sources based on the set par

Strona 4

6 Introduction 1.7 Contacting Daktronics If any problems or questions arise that are not discussed in this manual, contact Daktronics using any of t

Strona 5

Installation 7 Section 2: Installation The Venus DataStreamer software must be installed to the hard drive before use. To install the software to yo

Strona 7 - Section 1: Introduction

Configuration 9 Section 3: Configuration After installing the Venus DataStreamer software on the computer, the individual displays must be configure

Strona 8 - Figure 1: Table Dialog

10 Configuration 4. Select the type of communication that will be used, either "Direct Communication" or "Remote Communication"

Strona 9

Configuration 11 12. Click the down arrow next to Display Type and set whether the DAKTicker is an indoor display or an outdoor display as shown in

Strona 10 - Figure 3: Frame Type Toolbar

12 Configuration Rename a Display Once in the configuration window, a display can be renamed if necessary. To rename the display, click the desired d

Strona 11 - 1.5 Help Menu

Configuration 13 5. Select the type of communication that will be used, either "Direct Communication" or "Remote Communication".

Strona 12 - 1.7 Contacting Daktronics

ED13649 Product 1260 Rev 10– 22 July 2011 DAKTRONICS, INC. Copyright  2003-2011 All rights reserved. W

Strona 13 - Section 2: Installation

14 Configuration 12. The last screen in the Configuration shows all the information that was entered during configuration as shown in Figure 16. Tak

Strona 14

Configuration 15 Source Tab Note: The default values set here should only be changed if directed by Daktronics. 1. Place a checkmark in the Edit box

Strona 15 - Section 3: Configuration

16 Configuration Source Tab Note: The default values set here should only be changed if directed by Daktronics. 1. Place a checkmark in the Edit box

Strona 16

Configuration 17 Source Tab Note: The default values set here should only be changed if directed by Daktronics. 1. Place a checkmark in the Edit box

Strona 17

18 Configuration 2. Click the Driver Configuration tab. 3. If registered for this driver source, the box next to it is checked and the configurati

Strona 18 - Remove a Display

Configuration 19 Schedules Tab The Schedules tab allows the viewing of game schedules for the day sorted by league. 1. Click the Schedules tab as sh

Strona 19 - Figure 15: Naming a Display

20 Configuration Standings Tab The Standings tab allows the choice of the leagues from which standings data will be collected. 1. Click the check b

Strona 20

Configuration 21 5. Click OK to close the TSN Sport Properties window or click another tab to continue configuration. News Filter The News Filter l

Strona 21 - Source Tab

22 Configuration Teams The Teams tab allows the displayed names of teams in a specific league to be customized as shown in Figure 34. 1. Select the

Strona 22

Configuration 23 4. Click Add; the Data Links Properties window will open as shown in Figure 36. 5. Click Microsoft OLE DB Provider for ODBC Drive

Strona 23 - Filtering Tab

Table of Contents i Table of Contents Section 1: Introduction ...

Strona 24

24 Configuration 9. When the next Create New Data Source window appears, select Microsoft Access Driver (*mdb) and click Next as shown in Figure 39.

Strona 25 - Figure 28: Selecting Teams

Configuration 25 14. The dialog should now be the Data Link Properties window with the Connection tab selected as shown in Figure 42. Click the down

Strona 26 - Figure 31: News Tab

26 Configuration 3.6 Email Configuration Email Configuration sets the parameters that will be used for sending email notifications and operating sta

Strona 27 - Figure 32: News Filter Setup

Options 27 Section 4: Options To access the Options window, click the File drop-down menu and select Options. Two tabs are now available for configu

Strona 28

28 Options Click in the No Results Notification field and type in the desired notification message. Click OK to keep the change or Cancel to void the

Strona 29 - Properties

Options 29 The notifications are defined as follows: 5. Display Notification is sent when communication fails with a display. 6. Data Driver Notif

Strona 30 - Figure 39: Driver Selection

30 Options 4.3 Image Options Configuration Image Options tells the ticker display what to do when an image tag is not found. For more information on

Strona 31 - 3.5 NTP Configuration

Image Explorer 31 Section 5: Image Explorer To use images as part of a frame, they must first be located on the Internet or other sources and saved

Strona 33 - Section 4: Options

Creating Messages for a DAKTicker 33 Section 6: Creating Messages for a DAKTicker The creating and editing of messages takes place within the main s

Strona 34 - 4.2 Email Notification Tab

ii Table of Contents Test Email ...

Strona 35 - Test Email

34 Creating Messages for a DAKTicker 3. Depending on the driver(s) that are installed, several different types of information can be entered. When t

Strona 36 - Figure 48: Image Options Tab

Creating Messages for a DAKTicker 35 6. Click the Font tab to choose the type of font for the message and any other attributes the font should have.

Strona 37 - Section 5: Image Explorer

36 Creating Messages for a DAKTicker 6.4 Adding a DDE Frame Dynamic Data Exchange (DDE) frames are used to display information from other DDE compli

Strona 38

Creating Messages for a DAKTicker 37 10. In the Name field of the Items tab, enter the name of each column. Note: The DDE, Fields, and Items tabs ca

Strona 39 - 6.1 Creating a New Message

38 Creating Messages for a DAKTicker 16. From the File pull-down menu, click Save As to save the message and information. The message is now saved a

Strona 40 - 6.2 Adding a Text Frame

Creating Messages for a DAKTicker 39 7. Click the down arrow next to the Layout field to select a layout for the information on the display. See pre

Strona 41

40 Creating Messages for a DAKTicker 6.6 Adding a News Frame Several different categories of up-to-date news headlines can be displayed with Venus D

Strona 42 - 6.4 Adding a DDE Frame

Creating Messages for a DAKTicker 41 8. Click the arrow next to Background to set the DAKTicker’s background color. Note: This feature is available

Strona 43

42 Creating Messages for a DAKTicker 2. Click the Data tab as shown in Figure 71. Note: For this version of Venus DataStreamer software, the Driver

Strona 44

Creating Messages for a DAKTicker 43 9. Under the Item column, click into a field to make the field active. Use the down arrow to choose the informa

Strona 45

Table of Contents iii 9.6 Opening a Playlist ...

Strona 46 - 6.6 Adding a News Frame

44 Creating Messages for a DAKTicker 5. Click the arrow next to Background to set the DAKTicker’s background color. Note: This feature is available

Strona 47 - 6.7 Adding a Sports Frame

Creating Messages for a DAKTicker 45 6.9 Adding a Database Frame The Database frame allows information stored on private systems databases to be sho

Strona 48 - Figure 71: Sports Data Tab

46 Creating Messages for a DAKTicker 8. Click the down arrow next to the Layout field to select a format for the information to appear on the displa

Strona 49 - 6.8 Adding a Weather Frame

Creating Messages for a DAKTicker 47 6.10 Adding an Image Frame The Image frame is used to display images that are stored on a computer of network.

Strona 51 - 6.9 Adding a Database Frame

Creating Messages for the Panelized DataTrac 49 Section 7: Creating Messages for the Panelized DataTrac Creating and editing messages takes place wi

Strona 52

50 Creating Messages for the Panelized DataTrac 4. Once all the required fields and information are entered, click the Preview button to view the me

Strona 53 - 6.10 Adding an Image Frame

Creating Messages for the Panelized DataTrac 51 next to the color field and then click the desired color. 4. Within the Display tab, choose the ali

Strona 54

52 Creating Messages for the Panelized DataTrac 8. In the F ormat window, set the information style by highlighting the desired format on the left s

Strona 55 - DataTrac

Creating Messages for the Panelized DataTrac 53 3. Click the down arrow next to Select a Field to set the query information. This function allows th

Strona 57 - 7.4 Entering a DDE Field

54 Creating Messages for the Panelized DataTrac 5. Click in the Value field and enter the symbol of the exchange to be monitored, for example, NYSE

Strona 58 - Entering a Financial Field

Creating Messages for the Panelized DataTrac 55 8. Click in the first field under the Field column in the table and select the information to be dis

Strona 59 - Entering a Financial Table

56 Creating Messages for the Panelized DataTrac 16. To Show Only Specific Results, click this radio button as shown in Figure 97. Then click on the

Strona 60

Creating Messages for the Panelized DataTrac 57 7.6 Entering a News Table A variety of news headlines can be displayed on a Daktronics DataTrac. Fol

Strona 61

58 Creating Messages for the Panelized DataTrac 7. Click in the Width column to set the maximum number of characters to be displayed in the field.

Strona 62

Creating Messages for the Panelized DataTrac 59 14. The News Table overview will show all of the criteria entered as shown in Figure 105. Use the sc

Strona 63 - 7.6 Entering a News Table

60 Creating Messages for the Panelized DataTrac 3. Click the up and down arrows next to the Table Width field to set the number of columns which the

Strona 64

Creating Messages for the Panelized DataTrac 61 10. Click in the General column and set any necessary parameters for the field. 11. The Conditions

Strona 65 - 7.7 Entering a Sports Table

62 Creating Messages for the Panelized DataTrac 7.8 Entering Weather Information A variety of weather information can be displayed using Venus DataS

Strona 66

Creating Messages for the Panelized DataTrac 63 7.9 Entering Database Information Database information stored in private database systems may also b

Strona 67

Introduction 1 Section 1: Introduction This manual will assist in the installation and operation of the Venus® DataStreamer® software and display ne

Strona 68

64 Creating Messages for the Panelized DataTrac 8. Click in the Width column to set the maximum number of characters available for the field to be d

Strona 69

Creating Messages for the Panelized DataTrac 65 14. The Database Table overview will show the criteria that were entered as shown in Figure 122. Use

Strona 71

Conditionals 67 Section 8: Conditionals Conditionals allow the user to define parameters that will modify the data shown on a display versus the act

Strona 72

68 Conditionals 3. Type desired text. To set the text color, complete the following: 1. Click in the Set Color box. 2. Click in the field next t

Strona 73 - Section 8: Conditionals

Conditionals 69 Does not contain – If the value of the incoming data does not contain the set parameter, then the data will be displayed with the con

Strona 75

Playlist Manager 71 Section 9: Playlist Manager The Playlist Manager is responsible for sending saved messages to the server. A list of messages cur

Strona 76

72 Playlist Manager 1. Highlight the desired display from the left side of the screen. 2. Click Add Message and the dialog box will open. Navigat

Strona 77 - Section 9: Playlist Manager

Playlist Manager 73 2. Click Remove Message. The message will instantly be removed from the play list; however, until Update Display is clicked, the

Strona 78 - 9.3 Removing a Message

2 Introduction Conditional: A set format applied to data when the data satisfies a defined parameter(s). Duration: The length of time a frame remains

Strona 79 - 9.7 Scheduling a Message

74 Playlist Manager 2. Click in the Start Time field and adjust the start time of the message by either typing in the time or using the up and down

Strona 80

Venus DataStreamer Troubleshooting 75 Section 10: Venus DataStreamer Troubleshooting This section contains some symptoms that may be encountered whi

Strona 81

Introduction 3 1.4 Functions of the Venus DataStreamer Toolbar The following items are located on the toolbar of the main screen as shown in Figure

Komentarze do niniejszej Instrukcji

Brak uwag