Operation 17
3.4 Advanced Data Importing
Packages
Packages tell the DDM application what types of incoming data to look out for, similar to
what an ITF does for the display controller. Incoming data sources will typically include other
Daktronics products, such as an All Sport
®
controller, for scoring and timing information.
In order to utilize packages for importing data, there are three major steps to complete:
1. Create a Package Suite
2. Create an Input Port
3. Input Mapping
Create a Package Suite
1. Click the Package Suite Editor button .
2. Click Add to insert a new package suite (Figure 20).
3. Type a descriptive Name for the package suite.
4. Leave Type set to Ascii.
5. Click Package Collection, and then click the button to open the PackageSetting
Collection Editor window (Figure 21).
Figure 20: Package Suite Editor Window
Figure 21: PackageSetting Collection Editor Window
Komentarze do niniejszej Instrukcji